Sign in →

Test Code LAB1370 STREPTOCOCCUS PNEUMONIAE ANTIGEN

Additional Codes

Internal: 11381

External: SPNEUMAG

Beaker: LAB1370

PERFORMED AT

SBH LABORATORY

Specimen Requirements

Container Type: Sterile container
Specimen Type: Urine, random
Preferred Volume: 5 mL
Emergency Minimum Volume: 1 mL
Collection Procedure: Collect a random urine specimen.
Specimen Processing: Aliquot 5 mL of a random urine collection. Put in leakproof plastic container.
Store and Transport Refrigerated
Stability: Room Temp 1 day Refrigerated 1 week Frozen (-20 øC) 1 week
Unacceptable Condition: Leaking containers
Alternate Specimens: Urine collected with boric acid as a preservative.

Method

ICT Assay

Synonyms

Strep Pneumo Ag,S.Pneumo Ag,S.Pneumonia

CPT Codes

87899

Department

Microbiology

Test Schedule

Daily at SC Bend