Test Code LAB281 TYPE AND SCREEN (FOR TRANSFUSION ONLY)

Important Note

Testing for Transfusions at SCHS or HDH locations only

 

Additional Codes

Internal / External: TYPESC

Beaker: LAB281

PERFORMED AT

SBH LABORATORY
SRH LABORATORY

SMH LABORATORY

SPH LABORATORY

HDH LABORATORY

 

 

Specimen Requirements

Container Type: Pink or Lavender top tube (EDTA)
Specimen Type: EDTA whole blood
Preferred Volume: 6 mL
Emergency Minimum Volume: 2 mL
Specimen Processing: Transport at room temperature same day.  If not transported to Lab same day, store refrigerated.  Do not separate plasma.
Required Patient Info: Label on tube must contain full patient name and date of birth and must match requisition. No unlabeled samples accepted.
Unacceptable Condition: Hemolyzed cells
Alternate Specimens: Plain red top tubes

Method

Hemagglutination

Department

Blood Bank

Test Schedule

Daily at SCHS Bend

Test Includes

ABO; Rh; Antibody Screen

CPT Code / Price Quote Code / Billing Information

CPT Codes: 86900, 86901, 86850