Test Code LAB320 PROTIME-INR
Additional Codes
Internal: 10496
External: PTINR
Beaker: LAB320
PERFORMED AT
SBH LABORATORY
SRH LABORATORY
SMH LABORATORY
SPH LABORATORY
HDH LABORATORY
Specimen Requirements
Container Type: 3.2% Sodium Citrate Plasma (Blue Top)
Specimen Type: Whole blood or Citrated Plasma.
Preferred Volume: 1.8 mL or 2.7 mL whole blood; 2 mL plasma
Emergency Minimum Volume: 0.5 mL plasma
Collection Procedure: Fill blue top tube to indicator line. Test must be performed within 8 hours of specimen collection or be centrifuged at 2000 g for 15 minutes and freeze aliquot of plasma.
Specimen Processing: Specimens should be transported uncentrifuged or centrifuged with plasma remaining on top of the cells in an unopened tube kept at room temperature. If time interval between drawing and testing exceeds 8 hours, centrifuge specimen, separate plasma, recentrifuge, separate into clean plastic tube, and freeze at -20øC or less.
Required Patient Info: Anti-coagulation therapy
Unacceptable Condition: Refrigerated specimens. Severely hemolyzed, clotted samples or inappropriately filled blue top tubes, specimens more than 8 hours old that have not been separated and frozen at -20øC or less.
Stability:
Temperature | Time |
---|---|
Room Temp | 8 hours |
Refrigerated | Not acceptable |
Frozen (-20øC) | 2 weeks |
Method
Electromagnetic Mechanical Clot Detection
Synonyms
Prothrombin Time; PT & INR; INR and Protime; PT
Department
Coagulation
Test Schedule
Daily & STAT
Test Includes
PT and INR.
Turnaround Time
24 hours
CPT Codes / Price Quote Code / Billing Information
CPT Code: 85610