Test Code LAB347 URINALYSIS, AUTOMATED DIP ONLY
Additional Codes
Internal:10147
External:UADIP
Beaker: LAB347
PERFORMED AT
SBH LABORATORY
SRH LABORATORY
SMH LABORATORY
SPH LABORATORY
HDH LABORATORY
Specimen Requirements
Container Type: Sterile urine container.
Specimen Type: Urine, random
Preferred Volume: 10 mL
Emergency Minimum Volume: 2 mL
Collection Procedure: Collect a random urine specimen.
Specimen Processing: Aliquote 10 mL of a random urine specimen. Store and transport refrigerated.
Unacceptable Condition: Specimens that have been at room temperature longer than 2 hours. Specimens in boric acid tubes. Specimens submitted in a Urine Culture vacutainer tube.
Stability:
Temperature | Time |
---|---|
Room Temp | 2 hours |
Refrigerated | 24 hours |
Frozen (-20øC) | Not acceptable |
Method
Colorimetric
Synonyms
UA Dipstick; Urinalysis Macroscopic
Department
Hematology
Test Schedule
Daily and STAT
Test Includes
Color, Clarity, Specific Gravity, pH, Leukocyte Esterase, Nitrite, Protein, Glucose, Ketones, Blood
Turnaround Time
24 hours
CPT Codes / Price Quote Code / Billing Information
CPT Code: 81003