Test Code LAB40 VANCOMYCIN LEVEL, RANDOM
Additional Codes
Internal: LAB40
External: VANCRAN
Beaker: LAB40
PERFORMED AT
SBH LABORATORY
SRH LABORATORY
SMH LABORATORY
HDH LABORATORY
Specimen Requirements
Container Type: Plain Serum Tube (Red Top)
Specimen Type: Serum
Preferred Volume: 1 mL
Emergency Minimum Volume: 0.3 mL
Collection Procedure: Draw trough specimen within 30 minutes prior to infusion. Draw peak specimen 90 minutes after IV infusion completed or 60 minutes after the IM dose is given. Do not draw in a tube with a gel separator.
Specimen Processing: Separate serum from cells as soon as possible by centrifugation. Store and transport refrigerated.
Required Patient Info: Trough or peak specimen, Note times of dose and draw.
Stability:
Temperature | Time |
---|---|
Room Temp | 2 days |
Refrigerated | 14 days |
Frozen (-20 øC) | 1 year |
Method
KIMS
Synonyms
Vancocin
CPT Codes
80202
Department
Chemistry
Test Schedule
Daily & STAT
Reference Lab
SCHS